3-2
OPERATING THE TESTER
Daily Operations
Because Teradyne recommends that you keep the tester power on except for maintenance
and emergencies, daily operations do not include powering the tester on and off. For
information about those procedures see the “Power On/Off Sequence” section in Chapter 1
of this manual.
Verify that diagnostics have been run before you begin board testing. To ensure optimal test
results:
•
Set up for static safety.
•
Check the printer.
•
Inspect the fixture.
Set Up for Static
Safety
Antistatic safeguards which protect electronic components on the board-under-test include:
•
Static-dissipative work surfaces and grounding devices.
•
Conductive floor mats which plug into the wrist strap connection on the rear panel(s).
•
Operator’s wrist strap which plugs into the test jack panel.
TEST JACKS
ANALOG
DEBUG
DIGITAL
PULL-UPS
SCOPE
GROUND
NODE
FINDER
WRIST
STRAP
E
F
G
E
F
G
S
S
S
Test Jack Panel
Antistatic Mat
(customer-supplied)
Wrist Strap
Connect to
wrist strap
receptacle.
POWER
5A
UNSWITCHED
FILTERED
UNSWITCHED
UNFILTERED
WRIST
STRAP
START
PAD
GND
15A
ON
OFF
COMPUTER INPUT
Lower Rear Panel
Connect antistatic
mat to ground stud.
Wrist strap receptacle.
Z18OO