2-32
TESTER DESCRIPTION
AC Power Distribution
Assembly—Z1866,
Z1860, Z1850, Z1840,
Z1860M, Z1850M,
Z1840M
The AC power distribution assembly for the Z1866, Z1860, Z1850, Z1840, Z1860M,
Z1850M, and Z1840M testers contains power line monitoring circuitry which ensures that
acceptable electrical voltages are maintained within the system.
Important:
The LEDs are not safety indicators.
Item #
Name
Function
1
Power Input
Connects AC power.
2
AC Mains Breaker
15 A circuit breaker to switch AC power on/off.
3
User Outlets Breaker
5 A circuit breaker for user unswitched outlets.
4
Wrist Strap
Connects wrist strap or antistatic mats.
5
Ground
Connects to ground.
6
Switched System Outlets
Eight 120 VAC outlets provide AC distribution to
tester. When line monitor detects faults, it cuts power
to these outlets.
7
Fuse
Line monitor board protection.
8
LEDs
Green LED indicates AC power is on. It remains on as
long as AC is on. Red LED indicates detection of out-
of-range voltage or an emergency off signal.
9
Unswitched User Outlets
Four 120 VAC outlets to provide unswitched power.
120V
5A 50/60HZ
WRIST
STRAP
I
O
CB1
I
O
120V
5A 50/60HZ
T .16A 125V
INPUT PWR
CB2
15A
1
2
3
4
5
9
7
8
6
Содержание Z1800 Series
Страница 5: ......
Страница 9: ...IV...
Страница 11: ...VI...
Страница 93: ...2 40 TESTER DESCRIPTION...
Страница 115: ...3 22 OPERATING THE TESTER...