2-30
TESTER DESCRIPTION
AC Power Distribution
Assembly—Z1890,
Z1888, Z1880, Z1860-
NB, Z1808, Z1805,
Z1803
The AC power distribution assembly for the Z1890, Z1888, Z1880, Z1808, Z1805, and
Z1803 Plus testers contains power line monitoring circuitry which ensures that acceptable
electrical voltages are maintained within the system.
Important:
The LEDs are not safety indicators.
120V
5A 50/60HZ
I
O
T .16A 125V
CB3
FAULT
POWER
I
O
CB2
CB1
MAIN POWER
1
2
3
10
4
5
6
7
11
9
8
Z1890, Z1880, Z1808, Z1805, and Z1803 Plus
120V
5A 50/60HZ
I
O
T .16A 125V
CB3
FAULT
POWER
I
O
CB2
CB1
MAIN POWER
12
Z1888 (Addition of #12)
Item #
Name
Function
1
Fuse T.16A 125V
Line monitor board protection.
2
Fault light
Red LED indicates detection of out-of-range voltage or
an emergency OFF signal.
3
Power
Green LED indicates AC power is ON.
4, 5
Circuit Breakers
4: CB3 is the breaker for four unswitched user outlets.
5: CB2 turns off switched outlets inside the tester.
6
Ground
Connects to ground.
7
AC power cable
AC power cable hardwired to the tester.
8
25A main circuit breaker
Controls main power to the tester.
9, 10
User Outlets
9: Four 120 VAC outlets provide unswitched power.
10: Twelve switched outlets inside the tester.
11
Cable access cover
Removable cover attached by two screws and a gasket.
12 (Z1888)
Power detector cable
Signals AC line conditioner to test incoming AC power.