To Adjust the Vertical Scale
The vertical scale can be adjusted in
Coarse
or
Fine
mode.
●
Coarse
adjustment (take counterclockwise as an example): set the vertical scale in
1-2-5 steps namely 500uV/div, 1 mV/div, 2 mV/div, 5 mV/div, 10 mV/div …10 V/div.
●
Fine
adjustment: Adjust the vertical scale within a finer adjustment range to
improve vertical resolution. For example: 2 V/div, 1.98V/div, 1.96V/div, 1.94 V/div …1
V/div.
Use: If the amplitude of the input waveform is a little greater than the display full scale
under the current scale settings, and the amplitude would be too low if the next scale is
used, then fine adjustment can be used to optimise the amplitude of waveform display
to correctly view the signal details.
Press the
CH1
button on the front panel; then press the
Adjust
softkey to select the
desired mode. Turn the
VERTICAL Variable Knob
to adjust the vertical scale (clockwise
to reduce the scale and counterclockwise to increase).
The scale information in the channel label at the right side of the screen will change
accordingly during the adjustment. The adjustable range of the vertical scale is related to
the probe ratio currently set. By default, the probe attenuation factor is 1X and the
adjustable range of the vertical scale is from 500uV/div to 10 V/div.
Note: push the
VERTICAL Variable Knob
to quickly switch between
Coarse
and
Fine
adjustments.
To Adjust the Vertical Position
Turn the
VERTICAL Position Knob
to adjust the vertical position of the channel
waveform. Turn the knob clockwise to increase the vertical position and the channel
waveform moves up while counterclockwise to reduce the vertical position and the
waveform moves down. Push the knob to set the vertical position of the channel waveform
to zero.
During the adjustment, the vertical position information Volts Pos displays at the bottom of
the screen. The table below shows the range of vertical position according to the volt
scale.
Volt Scale
Range of Vertical Position
500 μV/div - 100 mV/div
±2V
102 mV/div - 1 V/div
±20 V
1.02 V/div - 10 V/div
±200 V
Содержание T3DSO1000
Страница 1: ...User Manual T3DSO1000 T3DSO1000A Series Digital Oscilloscope...
Страница 21: ...User Manual 3 Appearance and Dimensions Figure 1 Front View T3DSO1102 scope Figure 2 Top View T3DSO1102 scope...
Страница 22: ...4 User Manual Figure 3 Front View All scopes except T3DSO1102 Figure 4 Top View All scopes except T3DSO1102...
Страница 62: ...44 User Manual Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Страница 90: ...72 User Manual Figure 32 Relative Window Trigger...
Страница 92: ...74 User Manual Figure 33 Interval Trigger...
Страница 98: ...80 User Manual Universal Knob to select the desired value Figure 37 Pattern Trigger...
Страница 118: ...100 User Manual Figure 50 UART Trigger...
Страница 145: ...User Manual 127 function output Figure 63 Square Root...
Страница 205: ...User Manual 187 Figure 100 Option Information...