User Manual
99
UART/RS232 Triggering
This part shows a brief introduction and description for the operation of the UART
trigger.
1. Press
Setup
key to enter the
TRIGGER
function menu.
2. Press
Type
and select
Serial
.
3. Press
Protocol
and select
UART
.
4. Press
Trigger Setting
softkey to enter
UART TRIG SET
menu.
Figure 49 UART TRIG SET Menu
5. Press the
Source Type
softkey to select the source of the trigger (RX or TX).
6. Press the
Condition
softkey and set up the desired trigger condition:
●
Start
— the oscilloscope will be triggered at the position of the start bit.
●
Stop
—the oscilloscope will be triggered at the position of stop bits.
●
Data
— the oscilloscope will be triggered when a byte is found which is equal
to (not greater or less than) the specified data.
a.
Press the
Compare Type
softkey and choose an equality qualifier (
>
,
<
or
=
).
b.
Press the
Value
softkey to set the data value. Select a Data value is in
range of 0x00 to 0xff.
●
ERROR
— if the parity check has been set, and the checked parity bit shows
an error, then the oscilloscope will be triggered.
Содержание T3DSO1000
Страница 1: ...User Manual T3DSO1000 T3DSO1000A Series Digital Oscilloscope...
Страница 21: ...User Manual 3 Appearance and Dimensions Figure 1 Front View T3DSO1102 scope Figure 2 Top View T3DSO1102 scope...
Страница 22: ...4 User Manual Figure 3 Front View All scopes except T3DSO1102 Figure 4 Top View All scopes except T3DSO1102...
Страница 62: ...44 User Manual Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Страница 90: ...72 User Manual Figure 32 Relative Window Trigger...
Страница 92: ...74 User Manual Figure 33 Interval Trigger...
Страница 98: ...80 User Manual Universal Knob to select the desired value Figure 37 Pattern Trigger...
Страница 118: ...100 User Manual Figure 50 UART Trigger...
Страница 145: ...User Manual 127 function output Figure 63 Square Root...
Страница 205: ...User Manual 187 Figure 100 Option Information...