176 User Manual
To Set the LAN
Do the following steps to set the oscilloscope to communicate with PC via LAN:
1. Connect the oscilloscope to your local area network using the network cable.
2. Press the
Utility
button on the front panel to enter the UTILITY function menu.
3. Press the
IO Set
softkey to enter the I/O SET function menu.
4. Press the
Net Interface
softkey, then select LAN.
5. Press the
IP Set
softkey to enter the IP setting interface, see the picture below:
Figure 95 LAN Settings Interface
6. Press the DHCP softkey to turn on or turn off the DHCP.
●
On:
the DHCP server in the current network will assign the network parameters
(such as the IP address) for the oscilloscope.
●
Off:
you can set the IP address, subnet mask, gateway manually.
➢
Turn the
Universal Knob
to select the desired value.
➢
Push the
Universal Knob
to move horizontally.
➢
Press the Save softkey to save the current settings.
7. Use NI Visa to communicate with the oscilloscope.
Содержание T3DSO1000
Страница 1: ...User Manual T3DSO1000 T3DSO1000A Series Digital Oscilloscope...
Страница 21: ...User Manual 3 Appearance and Dimensions Figure 1 Front View T3DSO1102 scope Figure 2 Top View T3DSO1102 scope...
Страница 22: ...4 User Manual Figure 3 Front View All scopes except T3DSO1102 Figure 4 Top View All scopes except T3DSO1102...
Страница 62: ...44 User Manual Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Страница 90: ...72 User Manual Figure 32 Relative Window Trigger...
Страница 92: ...74 User Manual Figure 33 Interval Trigger...
Страница 98: ...80 User Manual Universal Knob to select the desired value Figure 37 Pattern Trigger...
Страница 118: ...100 User Manual Figure 50 UART Trigger...
Страница 145: ...User Manual 127 function output Figure 63 Square Root...