11-29
12-04
Custom Units (Line Speed) Display Mode
Range
【
0
】
:Drive Output Frequency is Displayed
【
1
】
:Line Speed is Displayed in Integer (xxxxx)
【
2
】
:Line Speed is Displayed with One Decimal Place (xxxx.x)
【
3
】
:Line Speed is Displayed with Two Decimal Places (xxx.xx)
【
4
】
:Line Speed is Displayed with Three Decimal Places (xx.xxx)
12-
04≠0,
line speed is displayed while the inverter is running or stopped.
12-05
Inputs and output Logic status display (S1 to S6) & RY1~2
Range
Read only(Panel read only)
Terminals S1-S6 are represented using two segments of each digit. Segment turns on when input is active. The
bottom segments of each of the first three digits are used to represent the digital outputs (R1, R2, DO1).
Segments turn on when output is active.
Example1:
S1~S6 are ON
S1 S2 S3 S4 S5 S6
Example2:
RY1, RY2 and PLC are ON
RY1
RY2
PLC