8-7
8.6
Forward and Reverse Jog
The jog forward command is used in combination with multi-function digital input function #6 (Jog Forward) and
the jog reverse command is used in combination with multi-function digital input function #7 (Jog Reverse).
Example: Jog Forward input terminal S5 (03-04 = 06) and Jog Reverse input terminal S7 (03-06=7)
Terminal representation for 230V: 1 ~ 2 HP, 460V: 1 ~ 3HP
E
DO2
24VG
S2
S4
S6
S8
24V
+10V
GND
AI1
AI2
DO1
DOG
S1
S3
S7
F1
F2
PI
AO1
AO2
E
Jog
Reverse
Switch
Connect shield
to control
ground
terminal
Common/
24VG
Control Terminals /
User Terminals
Jog
Forward
Switch
S5
Terminal representation for 230V: 3 ~ 150 HP, 460V: 5 ~ 425HP,
575V:1~10HP, 690V:15~270HP
Jog
Reverse
Switch
Connect shield
to control
ground
terminal
Common/
24VG
Control Terminals /
User Terminals
Jog
Forward
Switch
S(+)
S1
S3
S5
S7
24V
+10V
GND
-10V
GND
DO1
DOG
S2
S4
S6
S8
F1
F2
PO
PI
GND
AO1
AI1
AO2
AI2
E
24VG
S(-)
Содержание A510