4-294
Torque limit setting by using multi-function analog input AI2 (04-05)
Table 4.4.18 Torque limit analog input
04-05 (AI2)
Function
11
Positive torque limit
12
Negative torque limit
13
Regenerative torque limit (for both forward and reversal directions).
14
Positive/negative torque limit (positive and negative detection torque limit )
Set the analog input terminal (AI2) signal level (04-00), gain (04-07) and bias (04-08)
The default setting for the analog input AI2 is 0 -10V representing 0
– 100% of the motor rated torque).
Figure 4.4.128 shows the relationship between the output torque and the torque limit.
Output Torque (T)
(Positive torque limit, 04-05=11)
Motor Speed (N)
21-06
21-07
21-05
(Positive / negative torque limit, 04-05=14)
I: Forward driving
II: Reverse
regenerating
(Regenerative torque limit, 04-05=13)
(Negative torque limit, 04-05=12)
(Positive / negative torque limit, 04-05=14)
III: Reverse driving
IV: Forward generating
21-08
Figure 4.4.128 Analog input torque limit (AI2)
When the analog input is set to positive torque limit (value = 11) the torque limit is active in the third and fourth
quadrant.in the reverse direction (regenerative torque in the second quadrant).
When the analog input is set to negative torque limit (value = 12) the torque limit is active in the third and fourth
quadrant.
When the analog input is set to regenerative torque limit (value = 13) the torque limit is active in the second and
fourth quadrant can be controlled.
When the analog input is set to positive/negative torque limit (value = 14) the torque limit is active in all four
quadrants.
Содержание A510
Страница 25: ...3 11 Step 3 Make wire connections and place cover back Step 4 Fasten screw ...
Страница 38: ...3 24 690V 100 150HP 460V 125HP Power supply 690V 100 150HP M10 Terminal screw size T M10 M10 ...
Страница 45: ...3 31 3 690V 175HP 270HP ...
Страница 160: ...4 85 Frequency Reference Output Frequency 100 00 12 00 13 100 Figure 4 4 6 Frequency reference upper and lower limits ...