![TECO-Westinghouse A510 Скачать руководство пользователя страница 342](http://html.mh-extra.com/html/teco-westinghouse/a510/a510_instruction-manual_1072531342.webp)
4-267
18-Slip Compensation Parameters
18-00
Slip compensation gain at low speed
Range
0.00~2.50
18-01
Slip compensation gain at high speed
Range
-1.00~1.00
18-02
Slip compensation limit
Range
0~250%
18-03
Slip compensation filter
Range
0.0~10.0 Sec
18-04
Regenerating slip compensation selection
Range
0:
Disable
1:
Enable
18-05
FOC delay time
Range
1~1000 msec
18-06
FOC gain
Range
0.00~2.00
Slip compensation automatically adjusts the output frequency based on the motor load to improve the speed
accuracy of the motor mainly in V/F mode.
The slip compensation function compensates for the motor slip to match the actual motor speed to the reference
frequency.
Slip compensation adjustment in V/F mode
18-00:
Slip compensation gain at low speed
The adjustment of slip compensation gain at low speed follows the below procedure:
1. Set the rated slip and the motor no-load current (02-00).
2. Set the slip compensation (18-00) to1.0 (factory default setting is 0.0 in V / F control mode)
3. For the operation with a load attached, measure the speed and adjust the slip gain (18-00) accordingly
(increase in steps of 0.1).
- If the motor speed is lower than frequency reference, increase the value of 18-00.
- If the motor speed is higher than frequency reference, decrease the value of 18-00.
When the output current is greater than the no-load current (02-00), the slip compensation is enabled and the
output frequency increases from f1 to f2. Refer to Figure 4.4.99., the slip compensation value is calculated as
follows:
[ Output current (12-18) - no-load current of Motor 1 (02-00) ]
Slip Compensation Value = Motor rated slip frequency x
[ Rated current of Motor 1(02-01) - no-load current of Motor 1 (02-00) ]
Содержание A510
Страница 25: ...3 11 Step 3 Make wire connections and place cover back Step 4 Fasten screw ...
Страница 38: ...3 24 690V 100 150HP 460V 125HP Power supply 690V 100 150HP M10 Terminal screw size T M10 M10 ...
Страница 45: ...3 31 3 690V 175HP 270HP ...
Страница 160: ...4 85 Frequency Reference Output Frequency 100 00 12 00 13 100 Figure 4 4 6 Frequency reference upper and lower limits ...