![TECO-Westinghouse A510 Скачать руководство пользователя страница 326](http://html.mh-extra.com/html/teco-westinghouse/a510/a510_instruction-manual_1072531326.webp)
4-251
13-08=3:
3-wire initialization (230V/460V/690V)
Multi-function digital input terminal S7 controls the forward / reverse direction, and terminals S1 and S2 are set for
3-wire start operation and stop command.
Refer to Figure 4.4.2 and Figure 4.4.3 for 3-wire type operation mode.
Inverter input voltage (01-14) is automatically set to 220V (200V class) or 440V (400V class)
13-08=4:
2-wire initialization (230V/415V)
Multi-function digital input terminal S1 controls forward operation / stop command, and S2 controls reverse
operation / stop command. Refer to Figure 4.4.1.
Inverter input voltage (01-14) is automatically set to 220V (200V class) or 440V (400V class)
13-08=5:
3-wire initialization (230V/415V)
Multi-function digital input terminal S5 controls the forward / reverse direction, and terminals S1 and S2 are set for
3-wire start operation and stop command.
Inverter input voltage (01-14) is automatically set to 220V (200V class) or 440V (400V class)
Содержание A510
Страница 25: ...3 11 Step 3 Make wire connections and place cover back Step 4 Fasten screw ...
Страница 38: ...3 24 690V 100 150HP 460V 125HP Power supply 690V 100 150HP M10 Terminal screw size T M10 M10 ...
Страница 45: ...3 31 3 690V 175HP 270HP ...
Страница 160: ...4 85 Frequency Reference Output Frequency 100 00 12 00 13 100 Figure 4 4 6 Frequency reference upper and lower limits ...