Using via Digital Data Communication
------------------------------------------------------------------------------------
79
ALM:CONTain:CV
:Sets whether to contain CV_STS in LEVEL1_ALM
Function: Sets whether to contain CV_STS status in LEVEL1_ALM output condition
Same settings as FUNCTION Settings Items 74
Format:ALM:CONTain:CV <NRf>
Type:SET command, QUERY command
Parameters: 0 ・・・Does not include in LEVEL1_ALM
1 ・・・Includes in LEVEL1_ALM
Response: 0, 1
Restriction: Alarm response is returned for normal SET commands in the following conditions
・If analog option is not attached
・While operating as parallel operation slave unit
・
Sequence operation in progress
<Ex.>
ALM:CONT:CV 0
ALM:CONT:CV?
0
ALM:CONTain:PL
:Sets whether to contain PL_STS in LEVEL1_ALM
Function: Sets whether to contain PL_STS status in LEVEL1_ALM output condition
Same settings as FUNCTION Settings Item 76
Format:ALM:CONTain:PL <NRf>
Type:SET command, QUERY command
Parameters: 0 ・・・Does not include in LEVEL1_ALM
1 ・・・Includes in LEVEL1_ALM
Response: 0, 1
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・If analog option is not attached
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
ALM:CONT:PL 1
ALM:CONT:PL?
1
Содержание ZX-S-LN Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Страница 13: ...About this Product 10 This is blank page...
Страница 63: ...Useful Function 60 This is blank page...
Страница 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Страница 157: ...Special Loads 154 This is blank page...
Страница 199: ...Specifications 196 This is blank page...
Страница 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Страница 201: ...Appendix 198 ZX S 800LN 800LAN...
Страница 202: ...Appendix 199 ZX S 1600LN 1600LAN...