Special Loads
------------------------------------------------------------------------------------
151
Discharging Battery
Batteries can be discharged by constant-current.
An external resistive load and switch is required.
Constant-Current Discharging of Battery
The discharge resistance is derived from the following formula.
Open-Circuit Voltage of Battery (V)
R
L
= (Ω)
Discharge Current (A)
Open S1. Turn the power supply’s POWER switch ON.
Press the PRESET key and set the discharge current with the CURRENT dial.
See “Operating as a Constant Current Power Supply” on how.
Set the maximum voltage with the VOLTAGE dial.
Deriving the maximum output voltage(V
MAX
):
V
MAX
=open-circuit voltage of battery-discharge terminal voltage (V)
When finished, press the FUNC. key again to finalize settings.
Close S1 and press the OUTPUT key to begin testing.
When the discharge terminal voltage is reached, open S1 to stop discharging.
As long as S1 is closed, the battery will continue to discharge regardless of the power
supply’s output ON-OFF status.
Caution
Power Supply
+
-
S1
Battery
R
L
-
+
Содержание ZX-S-LN Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Страница 13: ...About this Product 10 This is blank page...
Страница 63: ...Useful Function 60 This is blank page...
Страница 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Страница 157: ...Special Loads 154 This is blank page...
Страница 199: ...Specifications 196 This is blank page...
Страница 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Страница 201: ...Appendix 198 ZX S 800LN 800LAN...
Страница 202: ...Appendix 199 ZX S 1600LN 1600LAN...