Controlling with External Analog & Contact Signals
------------------------------------------------------------------------------------
138
3.Output Voltage Control with External Resistance (C)
This sections describes how to set the output voltage zero
when the external resistance value is 10kΩ.
The output voltage is derived from the following formula.
Output Voltage[V]=Max. Output Voltage[V]- Max. Output Voltage[V]×
The output accuracy for the external resistance,
is the set voltage±(0.1%
of Rated Output Voltage).
Connecting
Connect the resistor to accessory connector terminals No.7 and 19.
IN
OUT
19
7
外部抵抗
0~10k
Ω
Setting Procedures
Set to parameter 4 (External Resistance Type C) according to the procedure on page 136.
MAX
0
外部抵抗
出
力
電
圧
CV_RC
10k
Ω
The External Resistance A, B, and C and the External Voltage cannot
be used together to control the output.
Caution
Ou
tpu
t v
olt
ag
e
External Resistance
External
Resistance
External Resistance[k
Ω
]
10
The system is a fail safe method and is such that if the External
Resistance opens, the Output Voltage will become zero.
MEMO
Содержание ZX-S-LN Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Страница 13: ...About this Product 10 This is blank page...
Страница 63: ...Useful Function 60 This is blank page...
Страница 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Страница 157: ...Special Loads 154 This is blank page...
Страница 199: ...Specifications 196 This is blank page...
Страница 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Страница 201: ...Appendix 198 ZX S 800LN 800LAN...
Страница 202: ...Appendix 199 ZX S 1600LN 1600LAN...