Using via Digital Data Communication
------------------------------------------------------------------------------------
95
[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
:Sets Output Voltage
Function:Sets the output voltage
Format:[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf>
Type:SET command, QUERY command
Parameters: 0.00~84.00
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
VOLT 80
VOLT?
80.00
[SOURce]:VOLTage:PROTection[:LEVel]
:Sets OVP Voltage
Function:Sets the OVP voltage
Format:[SOURce]:VOLTage:PROTection[:LEVel] <NRf>
Type:SET command, QUERY command
Parameters: 1.0~88.0
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
VOLT:PROT 88
VOLT:PROT?
88.0
Содержание ZX-S-LN Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Страница 13: ...About this Product 10 This is blank page...
Страница 63: ...Useful Function 60 This is blank page...
Страница 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Страница 157: ...Special Loads 154 This is blank page...
Страница 199: ...Specifications 196 This is blank page...
Страница 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Страница 201: ...Appendix 198 ZX S 800LN 800LAN...
Страница 202: ...Appendix 199 ZX S 1600LN 1600LAN...