Basic Operations
------------------------------------------------------------------------------------
34
Canceling Over Current Protection Operation
When Over Current Protection Circuit is triggered, the OUTPUT is
set to OFF and an error code (top) and alarm message (bottom)
will be displayed in the Number Display.
Error Code “E005” will be displayed in the top Number Display and
OCP will be blinking in the bottom Number Display
Hold down the OVP and OCP keys simultaneously for more than 1
second to erase the displayed error code and OCP.
Remove cause which triggered the OCP.
(Change CC set values, OCP set values, load status)
Press the OUTPUT key to start output.
When the OCP is triggered, the Falling slew rate setting, based
on the slew rate function, is set invalid and the output current is
immediately decreased.
MEMO
・During serial data communication, recovery from alarm status is
possible using commands.
・During parallel operation where the Master unit is the operating
normal, if any Slave unit triggers an alarm, the error code “E006”
will be displayed in the Master and functioning Slave units.
(Information concerning the alarm will be displayed on the Slave unit
that triggered the alarm)
MEMO
If the error code and OCP does not erase after holding down the
OVP and OCP keys, the power supply may be damaged. Turn power
off immediately and please contact Takasago or your retail store.
Caution
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
OUTPUT
PRESET
OVP
OCP
POWER
FUNC.
LOCAL
LOCK
DISPLAY
A
B
C
STORE
MEMORY
ALARM RESET
Содержание ZX-S-LN Series
Страница 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Страница 13: ...About this Product 10 This is blank page...
Страница 63: ...Useful Function 60 This is blank page...
Страница 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Страница 157: ...Special Loads 154 This is blank page...
Страница 199: ...Specifications 196 This is blank page...
Страница 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Страница 201: ...Appendix 198 ZX S 800LN 800LAN...
Страница 202: ...Appendix 199 ZX S 1600LN 1600LAN...