background image

ALARM RELAYS

There are eight alarm relays that provide normally open or normally closed 
contacts for each of the following alarms:

Visual Critical

Visual Major

Visual Minor

Audible Critical

Audible Major

Audible Minor

Auxiliary 1

Auxiliary 2

POWER SUPPLY 48 PIN CONNECTOR PINOUT

TOTAL ACCESS 4303 PLUS DC POWER SUPPLY

DC SUPPLY

CLEI: SLPOCDBC_ _

DC SUPPLY

PLUS

1202335L1

POWER
TEMP

61202335L1-22A

0401

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

FRONT PANEL LEDs

POWER

Off 

Both –48 VDC fuses blown, power not supplied to the shelf,
or incorrect polarity on the voltage supplied to the shelf

Green

Power supplied is the correct voltage and polarity; backplane
and hot insertion voltages correct

Amber

–48 VDC input and hot insertion voltage present; no back-
plane voltage

Red

–48 VDC input present; no backplane voltage and no hot 
insertion voltage

TEMP

Off Normal

Red

Over-temperature condition

DESCRIPTION

The Total Access

®

4303 

Plus

DC Power Supply is a removable assembly that provides

the voltages necessary for proper system operation.  The unit features LEDs for over-
temperature and DC output, an input fuse, and the ability to be hot-swapped when
used with another DC supply in the same chassis.  The supply interfaces to the Total
Access backplane through a 48-pin connector.  The unit accepts one or two –48 VDC
inputs from the backplane and supplies –48 VDC fused output for use with external
input logic, +5 VDC as hot insertion bias voltage for modules, and +2.1 VDC for back-
plane termination. In addition, the Total Access 4303 

Plus

DC Supply provides alarm

relay ouputs when installed in slot PS-A.

The following features are supported on the Total Access 4303 

Plus

DC Power Supply:

Thermal limit indicator with open collector output

DC status indicator on the 2.1 and 5 volt outputs with open collector output

Short circuit protection

Compatible with existing Total Access DC Power Supplies (P/N 1200335L1)

SPECIFICATIONS

Specifications

Input Voltage

–42 VDC to –56 VDC

Operating Temperature

–40°C to +65°C

Storage Temperature

–40°C to +85°C

Relative Humidity

Up to 95% noncondensing

Over Temperature Indication

90°C ±5%

–48 VDC Short Circuit Protection

Fused 1-amp slow blow

Backplane Voltage Short Circuit Protection

Self-mending

Compliance

FCC Part 15, UL 60950, NEBS Level III, 
GR-1089-CORE

Pin #

Row A Signal

Row B Signal

Row C Signal

1

AUD_CRIT_NO

AUD_CRIT_COM

AUD_CRIT_NC

2

AUD_MAJ_NO

AUD_MAJ_COM

AUD_MAJ_NC

3

AUD_MIN_NO

AUD_MIN_COM

AUD_MIN_NC

4

VIS_CRIT_NO

VIS_CRIT_COM

VIS_CRIT_NC

5

VIS_MAJ_NO

VIS_MAJ_COM

VIS_MAJ_NC

6

VIS_MIN_NO

VIS_MIN_COM

VIS_MIN_NC

7

AUX1_RLY_NO

AUX1_RLY_COM

AUX1_RLY_NC

8

AUX2_RLY_NO

AUX2_RLY_COM

AUX2_RLY_NC

9

–48V_A

PS_OK

PS_TEMP

10

–48V_B

2.1V

PS_PRESENT

11

2.1V

2.1V

2.1V

12

–48V_AB_RTN

2.1V

VCC

13

GND

GND

GND

14

GND

GND

PSRLY_CLK

15

GND

PSRLY_LOAD

PSRLY_DATAIN

16

FR_GND

–48V

PSRLY_DATAOUT

JOB

A

ID

#61202335L1-22A#

Отзывы: