INSTRUCTION MANUAL
58
15. Set the length of the part of the pipe which is to be flanged “Start pos.” to the
program (see chapter 6.4 Machine display and settings). A recommended value for this
setting is, that the display readings indicates 23mm + the thickness of the buffer plate
used, thus N (See chapter 6.3.4 Fastening of the pipe and clamp changing, item 8: Buffer
plates).
For instance, if the buffer plate is 4 mm thick, the setting of the scale should be 23mm +
4mm = 27mm.
NOTE!
¨
The value of the “Back pos.” has to be 60mm larger than the value of
the “Start pos.”. For example if the “Start pos.”= 25mm the “Back pos.” has to be
at least 25mm + 60mm= 85mm.
16. Turn the forming pin into flanging position, by turning the clamp control switch, at
the same time turning the control switch of the tool into the position
.
17. Drive the frame forward, until it stops.
18. Open the clamping jaws and place the pipe into the clamp. Put the end of the pipe
against the forming pin.
19. Close the clamping jaws by turning the clamp control switch.
1
Forming head from the side: 1. Digital measuring device (Mitutoyo)