INSTRUCTION MANUAL
48
6.4.2.2 EDIT PROGRAMS - SCREEN
Machine without pyrometer
Machine with pyrometer
Operator has to be logged in at least on level 1 to edit the programs. Up to 5000
programs can be saved to the machine memory. Programs can't be executed on this
screen.
- Set the program name by pushing the "program name" - field on the top of the screen.
- Browse through programs with arrows on the top of the screen or you can give the
program number to the top left corner on the screen.
- Change the unit by pushing the mm/inch- field.
- On “Back pos.”- field is shown the position where the work cycle starts. After that the
frame slides to start position of the forming. Change the value by pushing the field.
NOTE!
¨
! The value of the “Back pos.” has to be 60mm larger than the value of
the “Start pos.”. For example if the “Start pos.”= 25mm the “Back pos.” has to be
at least 25mm + 60mm= 85mm.
- On “Start pos.”- field is shown the position where the tool starts to turn the pipe end.
Change the value by pushing the field. Recommended value for this is 23mm + the buffer
plate thickness.
- On “Buffer plate 1”- field and “Buffer plate 2”- field is shown the thickness of buffer
plates. (See 6.2.4, point 8) Change the value by pushing the number field. The PLC
program will sum these values. When only one buffer plate is used, the value of the
“Buffer plate 2”- field is 0. Three buffer plates can be used, then add thickness values of
two plates to either buffer plate field value.
- When machine is equipped with pyrometer the heating stop temperature can be
changed by pushing “End temperature”- field.