INSTRUCTION MANUAL
20
5.4 START-UP INSPECTION
NOTE!
¨
Carry out a start-up inspection before using the machine. A wrong
direction of rotation or a wrong voltage may damage the machine.
NOTE!
¨
The start-up inspection is to be carried out only by a person authorized
to perform this duty by the employer.
Before using the machine, proceed as follows:
1. Measure the supply voltage of the machine and check, that it corresponds to the
tension and the frequency values indicated on the nameplate of the machine.
2. Heating equipment: Check the supplies of the compressed air, of the oxygen and of
the propane. If necessary, adjust the values to coincide with the data indicated in the
technical specifications (chapter 3.6 of the instruction book).
3. Check the amount of the hydraulic oil and of the lubrication oil of the machine (see
chapter 14. Maintenance).
4. Check the rotation direction of the hydraulic pump motor. Turn the main power switch
on and press the power on push button
, on the control panel. The hydraulic pump
motor will start. Check the rotation direction, indicated by an arrow on the end of the
motor. Should the rotation direction be wrong, change phases of the supply cable on the
terminal board.
5. Check that the flange forming tool turns in the direction indicated by the arrow (on its
body), by pressing the push-button
on the control panel.
6. Check the correct function of the switches and push-buttons of the control panel.