INSTRUCTION MANUAL
26
No.
Name
Function
1
Buffer plates
These plates regulate the final distance of the tool and the pipe
clamp.
See chapter 6.3.4 Fastening of the pipe and clamp changing, item 8:
Buffer plates.
These plates regulate the distance between the tool and the clamp
when the frame is in front position.
Thickness (N) of the plate chosen:
- For cold flanging S < N < S + 2
- For hot flanging S + 2 < N <2S
(S = wall thickness, N = thickness of the buffer plate)
Valid with 2.5 radius setting. Marks in housing.
Buffer plate set is delivered with the machine, order number as
spare: 4401438.
2
Gas heating parts.
(OPTIONAL)
Throttle valves of oxygen and
propane of main burner.
See separate part list, assembly drawing and leaflets.
Oxygen flow is determined by pressure in oxygen supply line and
position of throttle. Propane flow is determined by pressure in
propane supply line and position of throttle.
3
Potentiometer
Potentiometer adjusts the diameter of the flange, the rear and the
front position of the frame.
When driving moving frame towards the tool with manual control,
the movement stops at setting of the start. In order to drive the
moving frame (by manual control) into the foremost position, the
cam has to be moved back. In automatic flanging cycle the moving
frame stops to this limit in the end of cycle.
4
Limit switch S37
Limit switch S38
Clamp closed limit switch (S37)
Clamp open limit switch (S38)
Indicates that the pipe clamp is in closing position. Automatic cycle
does not start if limit is not on. NOTE! Clamp closing pressure is
engaged in automatic cycle when this limit is on.
5
Proximity switch B6
Correct position of spindle. The pilot lamp lights when the spindle is
in its correct position.
6
Limit switch, service door
Safety switch of service door, with heating system only!
7
Limit switch, hood
Safety switch indicates that the safety cover is open or closed.
Machine won’t start if the safety cover is open
8
Adjusting and locking device Regulation of the turning angle of the tool
9
Limit switches
(Optional heating system
parts)
Limit switch S 33 - burner arm back position.
Limit switch S 34 - burner arm front position (heating position in
flanging).
Limit switch S36 - burner arm heating start position (expanding
mode).
Reed switch B 3 - burner arm side position.
Reed switch B 4 - burner arm up position (heating position).
10
Digital measuring unit
Digital measuring unit shows the pipes inside radius.
11
Frequency converter
12
Main switch