SV 258 PRO (AG) User Manual
79
Select in the
Source
list the result which will be
compared with the threshold level:
PPV
,
RMS
,
LEQ
,
rolling
RRMS
and
RLEQ
or
Curve
.
Selected result defines the threshold type
– next
parameter in this box.
For
LEQ
the
Threshold
in dB should be defined in the
range 20dB
÷ 130dB,
For
PPV
and
RMS
three threshold levels should be
defined for X, Y and Z axis in the range 1 µm/s ÷ 100
mm/s.
For rolling
RLEQ
and
RRMS
also the
Rolling time
should be defined.
In the
Event Counter
position, you can select a
number of event conditions that should appear before
triggering the event and alarms.
Additionally, in the
Event counter mode
position you
can define the mode of counting events (
Periodical
or
Consecutive
).
In the
Periodical
mode, an event will occur if a trigger
condition appears within a certain period of time (
Event
counter period: Human Vib. Step
or
Velocity Step
) for
a certain number of times (
Event Counter
).
In the
Consecutive
mode, an event will occur if a trigger
condition appears the specified number of times (
Event
Counter
) consecutively in succession.
For
Curve
the
Reduction factor
should be defined in
the range 0.1 ÷ 1.9.
The Event counter is not used for the Curve source.
The exception is the case when the
User
standard is
selected with 1/3-octave spectrum
– see below.