USER MANUAL
Warsaw, 2020-08-21
Rev. 2.00
Copyright © 2020 SVANTEK.
All rights reserved.
SV 258PRO
BUILDING VIBRATION &
NOISE MONITORING
STATION
(firmware 958AG)
Страница 1: ...USER MANUAL Warsaw 2020 08 21 Rev 2 00 Copyright 2020 SVANTEK All rights reserved SV 258PRO BUILDING VIBRATION NOISE MONITORING STATION firmware 958AG...
Страница 2: ...n without permission is prohibited Trademarks Trademarks or registered marks in this manual belong to their respective manufacturers Microsoft and Windows are registered trademarks of Microsoft Corpor...
Страница 3: ...for a long period of time it is recommended to charge their batteries to 100 capacity Batteries should be charged at least once per 6 months If the storage period is longer than one year a discharge c...
Страница 4: ...ional accessories for SV 258 PRO 16 2 2 1 SV 208A Sound measurement set 16 2 2 2 SV 111 Vibration Calibrator 17 2 2 3 SV 36 Class 1 Sound Calibrator 17 2 2 4 SB 272 External rechargeable battery 17 2...
Страница 5: ...Events 41 4 3 9 Configuring presentation views Display 44 4 3 10 Managing files File 47 4 3 11 Configuring the remote communication Remote 49 4 3 12 Configuring system parameters System 52 4 3 13 Man...
Страница 6: ...ement with Class 1 sound results The monitoring station uses the 3G modem for the remote communication with the Internet SvanNET the relay server supports the connection between PC and the station all...
Страница 7: ...rying case for SV 207B SB 270 and accessories to SV 258 SvanNET Web interface and connectivity support 1 3 ACCESSORIES AVAILABLE SV 208A Sound measurements set Microtech Gefell Prepolarised condenser...
Страница 8: ...ed inside the second transportation case The SV 258 PRO station includes waterproof case with battery charging unit and connectors 1 controller 2 SVAN 958A Class 1 Vibration Sound Level Meter and Anal...
Страница 9: ...PRO Waterproof case The IP 67 waterproof case houses and protects main elements of the monitoring station Controller 3G modem SVAN 958A instrument other internal elements such as rechargeable battery...
Страница 10: ...lematic Note The valve must be closed when the station is used outdoors otherwise the case is not sealed against moisture The station case is equipped with four Souriau UTO type connectors for input s...
Страница 11: ...y to charge the battery after any total discharge Note The station should not be stored for a long time with a discharged battery Storing with batteries in discharged condition may damage them Note If...
Страница 12: ...devices are available on http svantek com support drivers software html Note Before starting upgrading be sure that your SvanPC software is Off If not please Exit it before starting any upgrading To...
Страница 13: ...socket type ENB 0B 304 for Channels 1 3 and TNC for Channel 4 All sockets ensure IEPE power supply for the accelerometers or microphone preamplifiers SVAN 958A when it works with the monitoring stati...
Страница 14: ...1 1 SP 270 3G Modem The 3G modem SP 270 provides fast data transfer over the Internet to a PC with standard Internet connectivity A 3G modem type GeMalto EHS6 Terminal is used GeMalto EHS6 Terminal u...
Страница 15: ...rom the mounting surface and outer case to prevent ground loops The SV 84 is a part of the SV 207B set that includes also metal mounting adapter Note See SA 84 Technical Specification on www svantek c...
Страница 16: ...ntained in the air Note Desiccator should be regenerated after some period of use when it changes colour to light grey by drying it for 3 hours in a temperature of 150 C Desiccator should be inspected...
Страница 17: ...el and frequency SV 36 Sound calibrator produces sound pressure of declared levels 94 or 114 dB at a frequency of 1 kHz This calibrator is equipped with autorun function It starts generation of the de...
Страница 18: ...ompletely discharge the battery and then charge it to 100 capacity 2 2 5 SB 271 Solar panel The SB 271 solar panel 40 W 17 5 V DC extends the working time of the monitoring station The size and weight...
Страница 19: ...ded that the batteries of SV 258 PRO and SB 272 are charged before going on site Note The monitoring station and the external battery have their own chargers which are incompatible SB 270 is a waterpr...
Страница 20: ...n the controller and SVAN 958A the green LED will be blinking During connection initialization or powering down phase it is blinking orange Colour of the 3G LED is green when there is a connection wit...
Страница 21: ...ed BAT 1 LED If the lid is closed all LEDs will be off but charging will continue 3 3 3 Bootstrap mode The bootstrap mode allows upgrades of the internal firmware of the controller There are two ways...
Страница 22: ...different APN In this case the APN must be entered manually either via the PC software or the SVAN 958AG menu path Menu Remote Modem Connection APN Note The station is supplied with SVAN 958A configur...
Страница 23: ...ining up the key on the plug and the socket then lock the connector by turning the ring clockwise only the ring close to the socket will rotate To disconnect cables push the connector towards the stat...
Страница 24: ...re includes checking connections with the instrument and the 3G modem Additionally system power internal temperature of the station and the battery state are checked During the test procedure the cont...
Страница 25: ...gether with ENTER or ESC Alt The third function of a key Save and S P can be used when the Alt key is pressed together with ENTER or ESC Note Simultaneous pressing of the Alt and Start Stop keys switc...
Страница 26: ...to change the mode of result presentation Display Mode Markers The Markers key Alt Shift enables marking the special events occurring during a measurement for example some sound or vibration disturba...
Страница 27: ...Menu key opens the list of recently used menu items lists of parameters lists of options and information screens This enables accessing most frequently used items quickly without the necessity of pas...
Страница 28: ...te of the instrument available memory standards fulfilled by the instrument etc You cannot change anything in such screens To scroll through the screen use the key To close such a screen press ENTER o...
Страница 29: ...together with icons The meanings of the icons are as follows play icon is displayed when the measurement is running plug icon is displayed when the instrument is powered from the external source stop...
Страница 30: ...so called logger files files with wave signal records so called wave files and files with settings so called setup files The memory is divided into to two partitions one partition is reserved for the...
Страница 31: ...l files stored in the memory can be downloaded to a PC via the SvanNET web service or the SvanPC software In this case the instrument should be connected to the PC via the Internet see Chapter 6 3 4 a...
Страница 32: ...fined units and range 10 0 V ms 2 10 0 V ms 2 for the Channels 1 3 and 50 0 V Pa 50 0 V Pa for the Channel 4 The Channel x sub list consists of three positions By Sensitivity By Measurement which are...
Страница 33: ...ect the By Measurement position from the Calibration x list and press Enter 2 Set the Calibration Level appropriate to the used calibrator ENT 3 Mount the accelerometer to the vibration calibrator for...
Страница 34: ...ring the calibration measurement the external disturbances acoustic noise or vibrations should not exceed a value of 100 dB when using a calibrator that generates a level of 114 dB Note To quit the ca...
Страница 35: ...d selection Standard and type of building are associated with so called criterion curve based on FFT or 1 3 Octave analysis In the Band position you can select two bands 1 80Hz and 1 315Hz in accordan...
Страница 36: ...ult Peak Max or RMS For the User standard the Building Type position is skipped because there are no predefined criterion curves You should create the criterion curve by yourself in the Building Type...
Страница 37: ...NTER The segment will be deleted without request for confirmation ENT 4 3 4 Setting the parameters for whole body vibration Human Vibration The instrument can simultaneously measure vibration accelera...
Страница 38: ...tants are applied to the Leq LAE L10 and L95 results Lmax and Lmin results are calculated with Fast and Slow constants simultaneously LFmax LSmax LFmin and LSmin The Results position opens a screen in...
Страница 39: ...the period of 60 seconds decrementing the counter visible on the display by one after each second After warming up the instrument will start the measurement at 10 01 Note The instrument doesn t switch...
Страница 40: ...vent signals will be recorded provided that any Event occurs The duration of such record will be calculated as follows 15 seconds prior the Event Event Duration 15 seconds after the event duration whe...
Страница 41: ...ment s memory Events are stored independently to the time history data and can be presented in a table as well as on a plot in the form of correlation of PPV and Dominant Frequency PPV results are pre...
Страница 42: ...RMS3 Rolling RMS1 Rolling RMS3 or Rolling RMS3 The condition will be met when Result 1 is greater than Result 2 After confirmation the selection with the ENTER key this condition logic will be shown i...
Страница 43: ...osition press the key and in the SMS Recipient screen select recipients from the list and press ENTER The Address Book position opens the screen with up to five addresses of alarm recipients ENT You c...
Страница 44: ...y position opens a screen which allows to configure displaying of measurement result and screen properties ENT 4 3 9 1 Selecting presentation modes Display Modes There are five display modes which you...
Страница 45: ...tch the result make the result field active and press the key together with Alt Alt Velocity mode The Velocity mode presents results for Peak Particle Velocity PPV and Dominant Frequency DF for three...
Страница 46: ...sults added to the summary results with the human vibration step is predefined Results stored with the velocity step as time history can be selected in the Results list of the Sound section Logger mod...
Страница 47: ...delay from pressing any key defined by the Power Saver Delay parameter the screen is dimmed or switched off automatically If it has happened the first press of any key will cause the screen switching...
Страница 48: ...e from the instrument s memory The Delete position opens a screen with three positions which you can select deselect Logger Files Setup Files and Wave Files ENT To delete all files of one type select...
Страница 49: ...r saving the Logger files and its size is equal to 14848 KB ENT 4 3 11 Configuring the remote communication Remote The Remote position opens a screen which allows to configure the parameters of the da...
Страница 50: ...card Depending on the SIM card several options are possible some of them are recognized by the modem none no verification required PAP CHAP MsChap denotes MsChap in version 1 Use SMS defines the SMS...
Страница 51: ...me a host server in case of dynamic IP address Default name is hostname dyndns org DYNDNS Username a user name in case of dynamic IP address Default name is login DYNDNS Password a user password in ca...
Страница 52: ...t position opens a screen in which you can enable disable the automatic measurement start right after the turning the instrument on without pressing the Start Stop key ENT 4 3 12 3 Checking the instru...
Страница 53: ...ower source the special warning will appear and the instrument will be turned off ENT 4 3 12 6 Programming I O port functionality Ext I O Setup The Ext I O Setup allows you to select the function of t...
Страница 54: ...to 100 nms 1 and displacement signal from 1 pm to 100 pm The reference level for sound measurements cannot be changed 4 3 12 8 Setting the RMS detector type RMS Detector The RMS Detector position ope...
Страница 55: ...ent type its serial number the current software version installed and the relevant standards which the instrument fulfils 4 3 13 Managing setup files Settings The Settings position opens a menu screen...
Страница 56: ...time there is an option to use Auto Name function Select the Number parameter in the Auto Name position From this moment all setup files will be named automatically by increasing the file number of th...
Страница 57: ...of SV 258 PRO can be established by one of two available methods TCP Client or TCP Server The TCP Client is a mode of main communication channel in which the 3G Modem is configured to initiate connect...
Страница 58: ...DynDns service consult http www dyndns org The Address Server is a Svantek own initiative of providing the instrument s current internet address In this mode SV 258 PRO provides its current internet...
Страница 59: ...e which usually is delivered as an option to SvanPC SvanPC with Remote Communication module is described in detail in the SvanPC User Manual In the SvanNET Quick Start Guide it is described how to ins...
Страница 60: ...etup GPRS On 4 Check the Access Point Name APN The default setting for the APN is internet It is possible that your Internet provider is using different APN In this case the APN must be entered manual...
Страница 61: ...m panel login php Before logging select your language clicking on the appropriate flag Once logged in you can use the web interface to manage the monitoring station Note Ask your local SVANTEK distrib...
Страница 62: ...ening SvanNET a so called Project VIEW displays measurement points located on the map appointed to this project and time history plots of four results measured in four channels This is so called MAP v...
Страница 63: ...the SELECT RESULTS pop up box you can select and unfold Channel and Profile positions clicking on them The Profile list consists of results which you can view Press OK to confirm the selection The TIM...
Страница 64: ...d time point on the time history plot to readout LAeq results for the measurement point in the right hand area The EVENT LIST tab displays the list of events registered within the selected period In t...
Страница 65: ...t events were superimposed 3 Scroll evnet records which include Date time of the event Event type measurement Point event Values PPV and dominant frequency for the axes Weekdays and Hours of monitorin...
Страница 66: ...this moment Other plots below display waveform and FFT spectrum for X Y and Z axis for the selected event in the list You can point the cursor to the plot area to readout the Velocity values The RESUL...
Страница 67: ...and off When you click the station it becomes active and the tools at the right panel will be dedicated to this particular station The station bar except station name with serial number includes five...
Страница 68: ...nt cursor on the appropriate button it will change its colour to blue and click it The WEB INTERFACE button switches you to the Live data view see Chapter 6 3 in which you can view measurement results...
Страница 69: ...RM in the pop up box and a new Alarm 1 with CONDITIONS ACTIONS and MEASUREMENT POINTS areas will appear Alarms are based on Conditions and relate to Actions that are default e mails to the specified r...
Страница 70: ...rage memory below the selected threshold System check if applicable o Alarm is generated when the system detects failure in execution of the system check procedure not live check Measurement stopped o...
Страница 71: ...anging the status compared to the previous check i e if at 8 15 there is power supply at 8 30 mains is off at 8 45 mains is still off the system will generate an alarm at 8 30 and will be still until...
Страница 72: ...the log select the required period of records to be displayed and rewind records Data transfer log which registers history of data transfers uploads In the upper line you can refresh the log select t...
Страница 73: ...station Configuration view see Chapter 6 3 2 in which you can configure measurement and instrument parameters The STORAGE button switches you to the Storage view see Chapter 6 3 4 in which you can dow...
Страница 74: ...2 09 1994 23 07 1986 1 23 07 1986 2 IN 1226 A IN 1226 B IN 1226 C User or switch Off Velocity measurements 2 Update the Instrument clock 3 Select the Building type criterion curve for some standards L...
Страница 75: ...in the SVANNET configuration box In this box you can set the Lower and Upper frequency and value define Units and define whether to include or not the lower and or upper frequency to the segment If Hu...
Страница 76: ...om three channels and measurements of sound pressure from fourth channel made with Velocity Step 2 records contained measurements of acceleration vibration from three channels and measurement of sound...
Страница 77: ...d in the file Statistical levels Note All measurement results and waveform are saved in the files with automatically defined names You can define both file names manually through the instrument interf...
Страница 78: ...de the event click Configuring conditions To configure the LIMITS condition click the LIMITS button and then set Duration and Interval in the TIME LIMITS configuration box Duration defines duration of...
Страница 79: ...that should appear before triggering the event and alarms Additionally in the Event counter mode position you can define the mode of counting events Periodical or Consecutive In the Periodical mode an...
Страница 80: ...ifferent profiles that will be compared RMS with RMS or rolling RMS RRMS with rolling RMS The condition will be met when the left result is greater than the right result The selected threshold conditi...
Страница 81: ...nected for example SP 272 alarm lamp Hold time defines the duration of this alarm type The SMS Alarm action sends the SMS note to the defined recipient s phones which are selected from the ADDRESS BOO...
Страница 82: ...this case you should select the required address and click OK You can add the contact by clicking the field You can Edit address book from the EVENT TRIGGER tab of the Configuration view 6 3 3 STATUS...
Страница 83: ...files from a single directory on the memory card and it initially shows the content of the current working directory In the Storage window you can 1 Download or delete individual files by clicking the...
Страница 84: ...torage temperature range SM 258 PRO and SA 250 40 C to 70 C 9 Working relative humidity range 0 100 RH Power Supply 10 Internal battery Europower EP 17 12 12 V 17 Ah 11 SV 258 PRO power consumption wi...
Страница 85: ...analyser Manual and data specification are available at http www svantek com 20 SV 84 accelerometer Triaxial accelerometer with sensitivity1000 mV g Specification is available at http www svantek com...
Страница 86: ...cations HSDPA Cat 8 HSUPA Cat 6 data rates DL max 7 2 Mbps UL max 5 76 Mbps EDGE Class 12 data rates DL max 237 kbps UL max 237 kbps GPRS Class 12 data rates DL max 85 6 kbps UL max 85 6 kbps 25 3G mo...
Страница 87: ...LIST OF RELATED DOCUMENTS 1 SvanNET User Manual www svantek com 2 SvanPC User Manual www svantek com 3 SV 84 Specification www svantek com 4 GeMalto EHS6 Terminal User Manual www gemalto com 5 SA 277...