42
Sun Fire V445 Server Installation Guide • November 2006
Powering On Remotely Using the
poweron
Command
The following instructions show you how to power on the server by using the
poweron
command from the ALOM sc
>
prompt. To use this command, you must
pay careful attention to the ALOM boot messages, as this procedure requires quick
entry of commands.
1. Ensure that your system console device is set up and active.
2. Turn on power to any peripherals and external storage devices.
Read the documentation supplied with the device for specific instructions.
3. If you have not already done so, connect the Sun Fire V445 server’s outlet plug of
each power cord to the power sequencer in the cabinet (if your type of cabinet
includes one), to a grounded outlet strip, or to a grounded AC power outlet.
Caution –
High leakage current. To prevent leakage current in excess of 3.5 mA, a
maximum of two power cords can be connected to a single branch circuit. The
remaining two power cords must be connected to a different branch circuit.
Note –
Each outlet must connect the server to a 15A circuit for North America and
Japan, and to a 10A or 16A circuit for Europe. Consult your local electrical codes for
any additional requirements. See the instructions provided with your cabinet for
information about the power sequencer.