Chapter 3
Setup and Power-On Procedures
37
5. Connect the Sun Fire V445 server’s outlet plug of each power cord to the power
sequencer in the cabinet (if your type of cabinet includes one), to a grounded
outlet strip, or to a grounded AC power outlet.
Caution –
High leakage current. To prevent leakage current in excess of 3.5 mA, a
maximum of two power cords can be connected to a single branch circuit. The
remaining two power cords must be connected to a different branch circuit.
Note –
Each outlet must connect the server to a 15A circuit for North America and
Japan, and to a 10A or 16A circuit for Europe. Consult your local electrical codes for
any additional requirements. See the instructions provided with your cabinet for
information about the power sequencer.
The other Sun system responds by displaying:
The terminal window is now a Tip window directed to the Sun Fire V445 server
through the other Sun system’s TTYB port. This connection is established and
maintained even when the Sun Fire V445 server is completely powered off or just
starting up.
Note –
Use a terminal tool, not a console tool. Some
tip
commands might not work
properly in a console tool window.
connected