Chapter 2
Installing a Sun Fire V445 Server Into a 4-Post Cabinet
13
Installing the Slide Assemblies
Be aware of the following guidelines.
Caution –
Ensure that you have stabilized the cabinet by extending its antitip legs
or bolting the cabinet securely to the floor.
■
Install the slide assemblies into the lowest available position.
■
Install additional servers from the base up in the cabinet.
1. Use the rack alignment template to locate and mark mounting holes on the front
and rear vertical rack rails.
See
“Locating the Mounting Holes” on page 11
2. Adjust the back mounting brackets to accommodate the depth of the cabinet.
Loosen the 8-32 lock nut on each of the back mounting brackets, until the mounting
brackets can move forward or rearward along the slide assembly.
FIGURE 2-7
Adjusting the slide assembly to the depth of the cabinet
Lock nut