Chapter 3
Maintaining the Server
3-49
▼
To Replace an Optional Solid State Drive
1. Power off the server and remove the server module from the chassis as
described in
“To Remove the Server Module From the Chassis” on page 3-13
.
Caution –
Do not operate the system with empty slots. Always insert a filler into an
empty slot to reduce the possibility of module shutdown.
2. Remove the main cover as described in
“To Remove the Main Cover” on
page 3-15
.
3. If necessary, remove the Sun Blade RAID Expansion Module (
“To Remove a
RAID Expansion Module” on page 3-38
).
4. Disconnect the cable from the SSD (see
FIGURE 3-25
).
FIGURE 3-25
Removal of the SSD Cable
5. Use a #2 Phillips screwdriver to remove the four screws securing the SSD to the
SSD mounting bracket.