Chapter 2
Powering On the Server Module, Configuring BIOS and Resetting BIOS, SP and CMOS
2-41
FIGURE 2-33
The Location and Default Setting of J51
11. With the pins shorted on jumper block J19, J44, and pins 2 and 3 of J51 (revision
2 MB only), remove the wrist strap’s grounding cord from the chassis, and
replace and secure the top cover.
12. Insert the server module into the chassis.
13. Insert the bootable USB flash drive into the USB port.
14. Power on the system by pressing the Power button.
Note –
You must press the power button to power on the server module. When the
server module has jumpers installed, it does not automatically power on when
inserted into the chassis.
■
When the server module is has jumpers installed, the amber Service Action
Required LED lights.
■
A message appears on the video console stating that the BMC was not found.
■
The system takes up to three minutes to boot.