4-2
Sun Blade X6450 Server Module Service Manual • May 2009
■
Use
Immediate Burn-In Test
to run a test script. Sun provides three diagnostic
scripts designed to test a full range of system resources.
■
Use
Advanced Diagnostics Test
to test a specific hardware component, for example,
a CPU or a hard disk.
Other selections on the Diagnostics main menu display information about the
system, create disk partitions, and display test results.
▼
To Access the Pc-Check Diagnostics
1. Shut down the server.
For instructions, see
Section 2.2, “Powering Off the Server” on page 2-4
.
2. Start the SP and access the web interface.
See the corresponding SP documentation collection for details.
3. Configure the PCCheck program. This configures how Pc-Check runs when the
SP is booted.
■
For ELOM:
a. From the main menu, click the Remote Control tab and the Remote Power
Control tab.
b. From the drop-down menu select the option to Boot from PCCheck.
c. Click Submit.
■
For ILOM:
a. From the main menu, click the Remote Control tab and the Diagnostics tab
b. Select the Manual option from the drop-down menu.
The drop-down menu offers the following choices:
■
Disabled – Pc-Check doesn’t run.
■
Enabled – Selects the abbreviated version, which takes about three minutes.
■
Extended – Selects the abbreviated version, which takes about 30 minutes.
■
Manual – Selects the manual version, which runs untill it is stopped by user
intervention.
Note –
Select the Manual option to complete this procedure.
c. Click Save.
Содержание Blade X6450
Страница 12: ...xii Sun Blade X6450 Server Module Service Manual May 2009...
Страница 14: ...xiv Sun Blade X6450 Server Module Service Manual May 2009...
Страница 74: ...2 44 Sun Blade X6450 Server Module Service Manual May 2009...
Страница 126: ...3 52 Sun Blade X6450 Server Module Service Manual May 2009...
Страница 148: ...A 2 Sun Blade X6450 Server Module Service Manual May 2009...
Страница 162: ...Index 4 Sun Blade X6450 Server Module Service Manual May 2009...