Chapter 3
Maintaining the Server
3-23
2. Power off the server and remove the server module from the chassis as
described in
“To Remove the Server Module From the Chassis” on page 3-13
.
Caution –
Possible chassis shutdown. Do not operate the system with empty slots.
Always insert a filler into an empty slot to reduce the possibility of module
shutdown.
3. Remove the main cover as described in
“To Remove the Main Cover” on
page 3-15
.
4. Locate the CF card under the RAID Expansion Module at the back of the server
module (see
FIGURE 3-8
).
Your server module might not have a RAID Expansion Module.
Note –
If the optional RAID Expansion Module is installed, you do
not
need to
remove the RAID Expansion Module to remove the CF card.
FIGURE 3-8
Replacing the Compact Flash
5. Grasp the card, push down slightly, and pull card out.
Installation is the reverse of this procedure.