Sun Blade X6450 Server Module Service Manual • May 2009
Caution –
Irreparable hardware damage and component failure can occur due to
overheating if battery is incorrectly installed. Do
not
mount the battery onto the
RAID Expansion Module. Safe installation of the battery for the Sun Blade X6450
server module requires that you mount the battery on the motherboard as described
in this procedure.
4. Orient the battery with the connector and cable facing toward the front of the
server (see
FIGURE 3-15
).
FIGURE 3-15
Installing a RAID Expansion Module Battery
5. Align the battery screw-hole flanges over the four screw hole stand-offs in the
motherboard.
6. Use a #2 screwdriver and the four screws to secure the battery to the
motherboard.
7. Secure the battery cable to the motherboard using the installed twist-lock.
8. Install the RAID expansion module as described in
“To Install a RAID
Expansion Module” on page 3-35
. Be sure to complete the steps that describe
how to connect and route the battery cable.