Chapter 3
Maintaining the Server
3-5
3.1.2
Monitoring the System and Components Using
the SP Web Interface
You can use the ELOM web interface or the ILOM web interface to monitor the status
of the server module, and investigate the system when the front panel Service Action
Required LED is on or blinking.
▼
To Monitor the System and Components Using
the SP Web Interface
1. Log in to the web interface, as described in your SP documentation.
2. View system and component information:
■
For ELOM:
ILOM 3.0 Startup
The blue, amber, green, and white LEDs blink three times, at
one second invervals (.5 sec On, .5 sec Off).
After the three blinks, the green LED goes to fast blink while
the ILOM performs power calculations (.125 sec On, .125 sec
Off).
When the system is ready to turn on, the green LED stays
On for 3 seconds. You can now press the Power button to
power on the host (go to main power mode).
Otherwise it goes to standby blink (.1 sec On, 2.9 sec Off).
TABLE 3-1
Front Panel LED Functions
(Continued)
LED Name
Description