5-4
Sun Blade X6450 Server Module Service Manual • May 2009
Note –
A network failure during the file upload will result in a timeout. This causes
the SP to reboot with the prior version of the firmware.
4. To set the IP address of the TFTP server, enter the following command:
->
set ServerIP=
xxx.xxx.xxx.xxx
Where
xxx.xxx.xxx.xxx
is the IP address of the TFTP server.
5. To set the file name of the combined
bmc.bios
image, enter the following
command:
->
set Filename=filename
a. To set the update method to overwrite current BMC settings, enter:
->
set SaveFlag=yes
b. To set the update method to preserve current BMC settings, enter:
->
set UpdateMethod=PreserveCMOS
6. Start the tftp download:
->
set Update=action
7. Select Yes to continue, or select No to exit.
Example:
5.1.3
Updating the BIOS from a DOS-Bootable USB
Disk
This procedure describes how to update the BIOS from a DOS-Bootable USB disk.
->
cd /SP/TftpUpdate
->
set ServerIP=
xxx.xxx.xxx.xxx
->
set FileName=filename
->
set Update=action
getting image...
getting image successfully.
prepare to update...
Prepare OK!
Update Successful
starting update...