Sun Blade X6450 Server Module Service Manual • May 2009
Caution –
Irreparable hardware damage and component failure can occur due to
overheating if battery is incorrectly installed. Do
not
mount the battery onto the
RAID expansion module. Safe installation of the battery for the Sun Blade X6450
server module requires that you mount the battery on the motherboard as described
in the relevant procedure in this manual.
3.4.6
Installing and Replacing a Fabric Expansion
Module
The procedures in this section describe how to install and remove a Fabric Expansion
Module (FEM). The module is installed on the left side of the center mounting
bracket.
▼
To Install a Fabric Expansion Module
1. Power off the server and remove the server module from the chassis as
described in
“To Remove the Server Module From the Chassis” on page 3-13
.
Caution –
Do not operate the system with empty slots. Always insert a filler into an
empty slot to reduce the possibility of module shutdown.
2. Remove the main cover as described in
“To Remove the Main Cover” on
page 3-15
.
3. Remove the protective cap from the fabric expansion module connector (see
FIGURE 3-19
).
The fabric expansion module connector is located on the left side of the center
support bracket.
Содержание Blade X6450
Страница 12: ...xii Sun Blade X6450 Server Module Service Manual May 2009...
Страница 14: ...xiv Sun Blade X6450 Server Module Service Manual May 2009...
Страница 74: ...2 44 Sun Blade X6450 Server Module Service Manual May 2009...
Страница 126: ...3 52 Sun Blade X6450 Server Module Service Manual May 2009...
Страница 148: ...A 2 Sun Blade X6450 Server Module Service Manual May 2009...
Страница 162: ...Index 4 Sun Blade X6450 Server Module Service Manual May 2009...