StecaGrid 3600/x
StecaGrid 4200/x
Isolation principle
No electrical isolation, transformer-less
Grid monitoring
yes, integrated
Insulation monitoring
yes, integrated
Residual current monitoring
yes, integrated
1)
Overvoltage protection version
Varistors
Reverse polarity protection
yes
Operating conditions
Area of application
coolcept: indoor rooms, with or without air conditioning
coolcept-x: indoor rooms, with or without air conditioning,
out of doors with or without protection
Climate protection class as per
IEC 60721-3-3
coolcept: 3K3
coolcept-x: 4K4H
Ambient temperature range
–15 °C ... +60 °C
Storage temperature
–30 °C ... +80 °C
Relative humidity
coolcept: 0 % ... 95 %, non-condensing
coolcept-x: 0 % ... 100 %, non-condensing
Altitude of site
≤ 2000 m above sea level
Pollution degree
PD3
Noise emission (typical)
31 dBA
Improper ambient gases
Ammonia, solvents
Fittung and construction
Degree of protection
coolcept: IP21 (housing: IP51; display: IP21)
coolcept-x: IP65
Overvoltage category
III (AC), II (DC)
DC connection
Type
Phoenix Contact SUNCLIX (1 pair)
Connection conductor cross-
section
Conductor cross-section 2.5 … 6 mm
2
Opposing connector
Opposing connector included in delivery
AC connection
Type
Wieland RST25i3 plug
EN
747,431 | Z09.2 | 18/02/2016
80
Содержание coolcept StecaGrid 1500
Страница 1: ...Installation and operating instructions EN coolcept coolcept x 747 431 Z09 2 2016 02 18...
Страница 57: ...Fig 20 Email confirming successful registration EN 747 431 Z09 2 18 02 2016 57...
Страница 85: ...Appendix EN 747 431 Z09 2 18 02 2016 85...
Страница 93: ...747 431 Z09 2 2016 02 18...
Страница 94: ......