n
Max. daily yield
: The maximum daily yield achieved
3)
n
Operating hours
: The operating hours during which the
device has been connected to the grid (including night-time
hours).
n
Total yield
: Yield since commissioning
n
CO
2
savings
: CO
2
savings achieved since commissioning
1)
Measurement is always displayed (cannot be switched off)
2)
Possible causes:
–
Internal temperature too high
–
User default Power limiter
–
Frequency too high
–
Controlled by grid operator (feed-in management)
–
Delayed increase in power after starting
3)
Can be reset to 0 via
Settings
▶
Reset max. vals.
An acoustic alarm sounds (approx. 4.5 kHz) when an event message
is displayed.
n
2 Sounds: Warning
n
3 Sounds: Error
The acoustic alarm is switched off with the factory default settings.
n
off
n
automatic
: Switches on for 30 seconds when a button is
pushed
n
Grid feed:
(factory setting)
–
Not feeding: Switches on for 30 seconds when a button is
pushed; then switches off
–
Feeding: Switches on for 30 seconds when a button is
pushed; then dims
Notice
–
A prerequisite for this is that you know the
parameters required for setting up the TCP/IP
network connection. Consult (further) technical
professionals if required.
–
DHCP is activated in the device ex-works. This
allows automatic integration of the device in
most networks.
Network settings, required for network communication, e. g. with an
Internet portal:
n
DHCP
: Switch DHCP on/off
n
IP address
: IP address of the inverter
n
Subnet mask
: Subnet mask of the inverter
n
Gateway
: IP address of the network gateway
Acoustic alarm
Backlight
TCP/IP network
EN
747,431 | Z09.2 | 18/02/2016
18
Содержание coolcept StecaGrid 1500
Страница 1: ...Installation and operating instructions EN coolcept coolcept x 747 431 Z09 2 2016 02 18...
Страница 57: ...Fig 20 Email confirming successful registration EN 747 431 Z09 2 18 02 2016 57...
Страница 85: ...Appendix EN 747 431 Z09 2 18 02 2016 85...
Страница 93: ...747 431 Z09 2 2016 02 18...
Страница 94: ......