5.
Switch on the AC miniature circuit breaker. The start page for
1st commissioning is shown on the display.
6.
Perform 1st commissioning and switch on the DC supply, as
described in
4.7 Initial commissioning of the inverter
4.7.1 Function
Initial commissioning starts automatically when at least the AC
connector has been installed and switched on as described
previously. If initial commissioning is not fully completed then it
starts again anew the next time the device is switched on.
Initial commissioning is a guided procedure that sets the following
information:
n
Display language
n
Date / Time
n
Country
n
Reactive power characteristic curve (if prescribed for the
selected country)
The following applies when setting the country:
n
The country set must always be the same as the country where
the inverter is installed. This ensures that the inverter will load
the specified net parameters of the respective country; for more
information, refer to the Countries table on the Steca
homepage,
www.steca.com/Wechselrichter-Wohnsiedlung.
n
The country can only be set once!
Contact the Steca Technical Support if you have set the wrong
country.
n
If the Countries table does not list your country, select a country
with stricter specifications.
n
The country setting does not affect the language used on the
display. The display language is set separately.
4.7.2 Operation
The check list for 1st commissioning is displayed:
n
The default display language is English.
n
The
Language
entry is selected.
n
The check boxes are not selected.
Conditions for starting
initial commissioning
Guided initial
commissioning
Setting the country
Starting 1st
commissioning
EN
747,431 | Z09.2 | 18/02/2016
39
Содержание coolcept StecaGrid 1500
Страница 1: ...Installation and operating instructions EN coolcept coolcept x 747 431 Z09 2 2016 02 18...
Страница 57: ...Fig 20 Email confirming successful registration EN 747 431 Z09 2 18 02 2016 57...
Страница 85: ...Appendix EN 747 431 Z09 2 18 02 2016 85...
Страница 93: ...747 431 Z09 2 2016 02 18...
Страница 94: ......