STATUS SCIENTIFIC CONTROLS
Installation, Commissioning & Routine Gas Testing
FGD10A-M Gas Detector
TD18/032
Issue:
10
Change Note:
1869
Page 52
9.1.17. Zero Suppression
The zero of the sensor may drift from time to time and as such it may be
desirable to suppress small fluctuations. These menu options allow the user
to hide these small variations on the display.
The Neg Zero suppression is used to mask readings below zero while the Pos Zero
suppression masks readings above zero.
The setting can be set between 0 and 10% of the sensor range as set by the
FSD value.
•
From the menu system select menu option:
Pos Zero
or
Neg
Zero
and press ENTER. The following screen will be displayed:
Neg Suppression
Edit
Pos Suppression
Edit
•
Using the buttons increase or decrease the reading to the
required value.
•
Press ENTER to accept the new alarm level,
will be
displayed
Note: Pressing the MENU button rather than the ENTER button
exits without any change.
•
Press the MENU button to exit the alarms option menu. On exit
the display will show
if no changes have been made
or if changes have been made.
Updated
No change
Data updated