SSI700 User Manual Operation, Display and Application Example
www.ssinverter.info
•
After you press
, the system saves the parameter setting first, and then
goes back to Level II menu and shifts to the next function code.
•
After you press
, the system does not save the parameter setting, but
directly returns to Level II menu and remains at the current function code.
Here is an example of changing the value of P3-02 to 15.00 Hz.
Figure 4-3 Example of changing the parameter value
In Level III menu, if the parameter has no blinking digit, it means that the parameter
cannot be modified. This may be because:
•
Such a function code is only readable, such as, AC drive model, actually
detected parameter and running record parameter.
•
Such a function code cannot be modified in the running state and can only be
changed at stop.
4.3 Definition and Operation of the Multifunction Key (APP)
You can define the function (command source switchover or rotation direction switchover)
of the multifunction key in P7-01. For details, see the description of P7-01.
4.4 Viewing Status Parameters
In the stop or running state, you can press on the operation panel to display status
parameters. Whether parameters are displayed is determined by the binary bits of values
converted from the values of P7-03, P7-04, and P7-05 in the hexadecimal format.
In stop state, a total of 13 status parameters can be displayed, as listed in the following
table.
Содержание SSI700
Страница 1: ......
Страница 3: ...Safety Information and Precautions...
Страница 7: ...Product Information...
Страница 12: ...Mechanical and Electrical Installation...
Страница 19: ...Operation Display and Application Examples...
Страница 42: ...Function Code Table...
Страница 64: ...Description of Function Codes...
Страница 131: ...EMC...
Страница 137: ...Selection and Dimensions...
Страница 141: ...Maintenance and Troubleshooting...