14215700-IG, Edition 15.0
May 2020, Original document
165
16 Zones (16 base stations per zone)
If defining 16 zones for a site with 256 base stations (selecting
16 Zones (16 base stations per
zone)
in the
field), the numbering of base stations could be the following:
Site
Zones
Max. Base Stations
RPN
Site 1
Zone 1
16
0 - 15
Zone 2
16
16 - 31
Zone 3
16
32 - 47
Zone 4
16
48 - 63
Zone 5
16
64 - 79
Zone 6
16
80 - 95
Zone 7
16
96 - 111
Zone 8
16
112 - 127
Zone 9
16
128 - 143
Zone 10
16
144 - 159
Zone 11
16
160 - 175
Zone 12
16
176 - 191
Zone 13
16
192 - 207
Zone 14
16
208 - 223
Zone 15
16
224 - 239
Zone 16
16
240 - 255
Note
: The physical base station number in a zone can be less than 16,
but the RPN assigned to it must be within the defined RPN range. If you
move the base station to another zone, RPN must be changed accord-
ingly.
32 Zones (8 base stations per zone)
If defining 32 zones for a site with 256 base stations (selecting
32 Zones (8 base stations per
zone)
in the
field), the numbering of base stations could be the following:
Spectralink IP-DECT Server 200/400/6500 and Virtual IP-DECT Server One Installation and Configuration Guide