Appendix B. Specifications
52
RXT-150 Power Requirements
Source
Requirements
Power Cable
The power cable included with RXT-150 is a standard, three conductor, 18 AWG power
cord safe for 120-volt use in the United States and Canada. The cable has a molded
NEMA 5-15P male connector to plug in the wall and a molded IEC 60320-type female
connector to plug in the RXT-150 unit.
Note:
To use the RXT-150 outside of North America, the power cord
must meet the specifications for that country.
220 Volt-AC Power Cord for Use in North America
The criteria for a 220-volt AC power cord for the RXT-150 are as follows:
• Power cord must have a molded NEMA 6-15P attachment plug on one end.
• Power cord must have a molded IEC 60320-type female connector to connect to the
RXT-150.
• Cordage must be SJT type, three-conductor, 18 AWG minimum.
• Power cord must comply with local electrical code.
220 Volt-AC Power Cord for International Use
The criteria for an international 220-volt AC power cord are as follows:
• Power cord must have an attachment plug of the proper type, rating, and safety
approval for the intended country.
• Power cord must have a molded IEC 60320-type female connector to connect to the
RXT-150.
• Cord must be a flexible, HAR (harmonized) type H05VV-F, three conductor, cord
with minimum conductor size of 0.03 square inches (1.0 square millimeter).
Input Voltage
100/240 VAC
Input Power
18 watts typical, 140 watts peak
Current
1,4 - 0,6 Amps.
Input Frequency
50/60 Hz
Fuse rating