Chapter 5 Function parameter
90
Ch
ap
ter 5
0: read; 1: not read.
F6.14~
F6.15
Reserve
F6.16 Monitor selection 2
1Kbit/100bit
10bit/1bit
d0.04
☆
parameter number parameter series number
The assigned group d0 parameter can be shown in the bottom row of the double display.
F6.17 Power correction coefficient
0.00~10.00
1.00
☆
Frequency converter with motor running, the display output power (d0.05) is different with
the actual output power, through the parameters, adjust the converter display power and the actual
output power corresponding relation.
F6.18
Multifunction
key definition 1
UP key is defined as add function key
0
0
☆
UP key is defined free stop
1
UP key is defined Forward running
2
UP key is defined Reverse running
3
UP key is defined Forward Jog running
4
UP key is defined Reverse Jog running
5
UP key is defined UP function key
6
UP key is defined DOWN function key
7
F6.19
Multifunction
key definition 2
DOWN key is defined as subtract function key
0
0
☆
DOWN key is defined free stop
1
DOWN key is defined Forward running
2
DOWN key is defined Reverse running
3
DOWN key is defined Forward Jog running
4
DOWN key is defined Reverse Jog running
5
DOWN key is defined UP function key
6
DOWN key is defined DOWN function key
7
Define the function keys of the user-defined keys
0: The multifunction key define 1 as the add function key.
Under the monitor menu, the add function key proceed the add modify of the keyboard setting
frequency through F0.01.
Under the parameter selection menu, The add function keys adjust the parameter selection
Under the parameter modify menu, the add function keys adjust the parameter value.
The multifunction key define 2 as the subtract function key.
Under the monitor menu , the subtract function keys proceed the subtract modify of the
keyboard setting frequency through F0.01 .
Under the parameter selection menu, The subtract function keysadjust the parameter selection
Under the parameter modify menu, the subtract function keys adjust the parameter value.
1:Multifunction key is defined free stop key.
The key is effective under Parameter selection monitor menu, the inverter is free stop. After
free stop , no startup command , after 1S, it is allowed restart .
2:Multifunction key is defined as FWD Forward funning key.
Under monitor menu, the key is effective under Parameter selection menu, the inverter is
forward running.
3:Multifunction key is defined as FEV reverse running function key.
The key is effective under Parameter selection monitor menu, the inverter is forward running.
4: Multifunction key is defined as Forward Jog running key.
The key is effective under Parameter selection monitor menu, the inverter is forward jog
running.
5: Multifunction key is defined as Reverse Jog running key.
The key is effective under Parameter selection monitor menu, the inverter is reverse jog
running.
6: Multifunction key is defined as UP function key.
The key is effective at any time, the control way is same as terminal control UP.
7: Multifunction key is defined as DOWN function key.