Chapter 5 Function parameter
38
Ch
ap
ter 5
149.
F3.12 Braking utilization rate
0% to 100%
100%
☆
150.
F3.13 Ac/deceleration mode
0: Linear acceleration and
deceleration
1:S curve acceleration and
deceleration A
2:S curve acceleration and
deceleration B
0
★
151.
F3.14 Proportion of S curve start-section 0.0% to (100.0%to F3.15)
30.0%
★
152.
F3.15 Proportion of S curve end-section 0.0% to (100.0% to F3.14)
30.0%
★
5-1-6.
F4 Group - V/F control parameters
No. Code
Parameter name
Setting range
Factory
setting
Chan
ge
153.
F4.00 V/F curve setting
0 to11
0
★
154.
F4.01 Torque boost
0.0% Automatic torque boost
0.1% to 30%
0.0%
★
155.
F4.02 Torque boost cut-off frequency
0.00Hz to F0.19(maximum
frequency)
15.00
Hz
★
156.
F4.03 MultipointV/F frequency point 1
0.00Hz to F4.05
0.00Hz
★
157.
F4.04 Multipoint V/F voltage point 1
0.0% to 100.0%
0.0%
★
158.
F4.05 Multipoint V/F frequency point 2
F4.03 to F4.07
0.00Hz
★
159.
F4.06 Multipoint V/F voltage point 2
0.0% to 100.0%
0.0%
★
160.
F4.07 Multipoint V/F frequency point 3
F4.05 to b0.04 (rated motor
frequency)
0.00Hz
★
161.
F4.08 Multipoint V/F voltage point 3
0.0% to 100.0%
0.0%
★
162.
F4.09 Slip compensation coefficient
0% to 200.0%
0.0%
☆
163.
F4.10 Overexcitation gain
0 to 200
80
☆
164.
F4.11 Oscillation suppression gain
0 to 100
0
☆
165.
F4.12 V/F separation voltage source
0 to 9
0
☆
166.
F4.13 V/F separation voltage digital setting 0V to rated motor voltage
0V
☆
167.
F4.14 V/F separation voltage rise time
0.0s to 1000.0s
0.0s
☆
5-1-7.
F5 Group - Vector control parameters
No. Code
Parameter name
Setting range
Factory
setting
Chan
ge
168.
F5.00 Speed loop ratio G1
1 to 100
30
☆
169.
F5.01 Speed loopintegral T1
0.01s to 10.00s
0.50s
☆