Chapter 5 Function parameter
88
Ch
ap
ter 5
parameters 1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
DI Input status
Output torque
Output power
Output current
(Hz)
Bus voltage
(V)
Set frequency
Running frequency
Output voltage
DO Output
AI1 Voltage
AI2 Voltage
(Hz)
Count
Reserve
Length
Load speed
PID Setting
(A)
(kW)
(%)
(V)
(V)
(V)
Figure 5-15:The figure is theRunning status 1
If the above parameters need to be displayed in operation, firstly set its position to 1, and then
set at F6.01 after converting the binary number to the hexadecimal number.
For example, if the load speed needs to be displayed in operation, the 14th in F6.01 should be
setting to 1, if the AI voltage need to be displayed in operation, the 9th in F.6.01 should be setting
to 1. If all of the related position are setting to 1 per the requirement, the data are show as follow:
1 0
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1 1
1 1
0 0
0 1
1 0
1 0
1
1
0
1
tag
number
number
The data will divided to 4 group,
tag number
15-12
11-8
7-4
3-0
number
0111
1010
0100
1111
After check the comparison of the binary number and the hexadecimal number, the data is
0x7A4F.
Binary Hexadecimal
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Binary
Binary
Binary
Hexadecimal
Hexadecimal
Hexadecimal
F6.02 Running status display parameters 2
0x0000 ~0xFFFF
0000
☆
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Present charge time(Min)
Line speed
Rest time of running
Running frequency2(Hz)
High speed pulse input
frequency(kHz)
PLC range
PID feedback
Present running time(Min)
High speed pulse input
frequency(Hz)
Communication parameters
encoder feedback speed(Hz)
Assistance frequency B
display(Hz)
Main frequency A display(Hz)
Ordering torque
Remain
Synchronous machine
wheel position
Figure 5-16:Run display 2
If the above parameters need to be displayed in operation, firstly set its position to 1, and then
set at F6.02 after converting the binary number to the hexadecimal number.
Running status display parameters, which is used to set the parameters that can be viewed
when the inverter is in operation.
There are 32 parameters available for viewing, select desired status parameters according to