Chapter 5 Function parameter
109
Ch
ap
ter 5
Running
direction
Time(t)
... ...
E1.19
E1.00
E1.21
E1.01
E1.02
E1.14
E1.25
250ms Pulse
DO or RELAY output
E1.23
E1.20
E1.18
Figure 5-31:Schematic diagram of simple PLC
E1.17
Simple PLC power-down
memory selection
Units digit power-down memory selection
11
☆
power-down without memory
0
power-down with memory
1
Tens digit
stop memory selection
stop without memory
0
stop with memory
1
PLC "Power-Down With Memory" means that the PLC operating stage and frequency before
power-down are memorized, and then it will continue to run from the position of the memorized
stage in next power-on. If Power-Down Without Memory is selected, the PLC process will restart
from the starting position for each power-on
PLC "Stop With Memory" means that the PLC operating stage and frequency before stop are
recorded, and then it will continue to run from the position of the recorded stage in next run. If
Stop Without Memory is selected, the PLC process will restart from the starting position for each
start.
E1.18 0 stage running time T0
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.19 0 stage ac/deceleration time selection
0 to 3
0
☆
E1.20 1 stage running time T1
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.21 1 stage ac/deceleration time selection
0 to 3
0
☆
E1.22 2 stage running time T2
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.23 2 stage ac/deceleration time selection
0 to 3
0
☆
E1.24 3 stage running time T3
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.25 3 stage ac/deceleration time selection
0 to 3
0
☆
E1.26 4 stage running time T4
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.27 4 stage ac/deceleration time selection
0 to 3
0
☆
E1.28 5 stage running time T5
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.29 5 stage ac/deceleration time selection
0 to 3
0
☆
E1.30 6 stage running time T6
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.31 6 stage ac/deceleration time selection
0 to 3
0
☆
E1.32 7 stage running time T7
0.0s(h) to 6500.0s(h)
0.0s(h)
☆