47
d:series amplifiers
manual
maintenance and update
screen and meter calibration
The meter screen calibration procedure consists of several steps:
1. Select meter calibration in the system screen of the touch screen.
2. Confirm the calibration process in the pop up window
3. Send a 1 kHz sine with -6dBFS on all channels of the amplifier.
4. Confirm the calibration process in a second pop up window to start the meter calibration
5. After a successful calibration process a pop up message will show up to inform you that the process
was successful.