Specific installation tips for posts
SUPPORT WITH POSTS FOR GD2
Without thermal bridge
The outer post section P or the post clip PC is 70 mm longer than the inner post section P in relation to assembled
support posts (= HN + HG). The male sliding-in detail must be ground off over 70 mm for standard posts P + P
110/100. Position the posts over the PUs at the bottom.
With thermal bridge
The outer post section P or the post clip PC is 70 mm longer than the inner post section P in relation to assembled
support posts (= HN + HG). The thermal bridges and post clip base PC have the same length as inner support
post P. The male sliding-in detail must be ground off over 70 mm for thermal discontinuous posts P + P with Y16P
110/116. Put the posts over the PUs at the bottom.
For corner posts with a thermal bridge see the instructions on page 47
110 mm
181 mm
70 mm
HG + HN
PCB
P
PC
70 mm
HG + HN
110 mm
100 mm
P
P
110 mm
197 mm
70 mm
HG + HN
P
PCB
Y16P
PU
HG + HN
110 mm
116 mm
70 mm
P
Y16P
Y16P