E_MH_Installation_instructions_Skylux_Climax
20/11/2020
74/88
Side finish of saddle roof
NON-THERMAL BRIDGE SADDLE ROOF
The visible side supports are provided with an L16P (with C2CX seals), a CLL (with CL16 or CL32 clips) or a CLSL
(with screw-in type CLSB with CLST clips). At the top of the ridge this side finish will be covered by the ridge end
panel (NASZ). Use 4 coated screws (ZSG) for this.
SADDLE ROOF WITH THERMAL BRIDGE
The side finish of a thermal bridge saddle roof is completed with the ZDC that is slid over the side support (ZD)
using the thermal bridge (Y16P). Cut the ZDC profiles to ensure they fit perfectly in the ridge.
ZSG
ZSG
L16P/CLL/CLSL
ZSG
ZSG
D1/D2/D3