| 89
Specifications |
GN70/MX610/MX612 Operator and Installation Manual
MX61xJB junction box
MX610JB
MX612JB
POWER
Local supply
12/24 VDC, +30 - 10%.
Consumption local supply
0,3 - 5 A
CAN bus load dependent
NMEA 2000 LEN* (50 mA)
1
3
Output for CAN bus supply
15 VDC, +/- 5%, 4 A max
ENVIRONMENT
Temperature, operation
-15°C to +55°C (5°F to 131°F)
Temperature, storage
-30°C to +70°C (-22°F to 158°F)
Protection
IPx2
MECHANICAL
Weight
0,9 kg (2 lbs)
4.4 kg (9.5 lbs.)
Size (width x height x depth)
211 x 180 x 60 (mm)
340 x 250 x 100 (mm)
Mounting
Bulkhead
Material
P Anodized
aluminium
Aluminum
Color
Black
Cable inlet
Slots: 9 x 95 mm and 18
x 45 mm
(0.4” x 3.7” and 0.7” x 1.8”)
Rubber cable glands
Data I/O
NMEA 2000
1x CAN bus
NMEA 0183 Ver. 4.0
4x - Bidirectional RS-422
Serial ports (+/-5 V)
12x - Bidirectional RS-
422 Serial ports (+/-5 V)
Baud rate
4800 (default) configurable by GN70/MX61x.
Port 2, 6 and 10 RX are for RTCM data only.
Port 3 (antenna), 7 and 11 are high speed ports and
will reset to 19,200 baud at power on.