82 |
Wiring |
GN70/MX610/MX612 Operator and Installation Manual
Central alarm panel with direct I/O interface
The interfacing described below applies for central alarm panels that use direct lines for alarm,
mute and acknowledge. For alarm panel using serial interface, refer to “IEC61162-1/2 (NMEA
0183) Devices” on page 79.
From the GN70/MX61x unit we are using the same two wires (red and blue) as for external
alarm relay connection.
Under normal operation you will see 12/24 V between these two wires. In an alarm situation,
or when power is lost, you will see no voltage.
12 - 24 V DC
+ _
CENTRAL ALARM PANEL
(12 - 24 V DC)
ALARM
1
4
3
2
External alarm wiring Connection
Pin
Color
Description
1
Black
Battery (-)
2
Blue
External Alarm
3
Yellow
External MOB
4
Red
Battery (+), 12 - 24 V DC
1
1
8
2
3
4